I'm on your latest kp49 for 24h, no reboots or strange behavior, 720 recording works fine, on dsp profile set @250-900. These are sr_vdd1_voltage values: 250 MHz sr_vdd1_voltage 23-34 500 MHz sr_vdd1_voltage 36-48 550 MHz sr_vdd1_voltage 35-54 600 MHz sr_vdd1_voltage 38-60 720 MHz sr_vdd1_voltage 52-60 805 MHz sr_vdd1_voltage 48-60 850 MHz sr_vdd1_voltage 52-60 900 MHz sr_vdd1_voltage 53-60 How can I check what voltage is best to use, since current OPP voltage as calculated by SR is lower than set by dsp profile? Thanks in advance...